Local Law 11 (FISP) in NYC: What Building Owners Must Do
Under local law 11 nyc, officially known as the Facade Inspection & Safety Program (FISP), owners of buildings taller than six stories must hire a Qualified Exterior Wall Inspector (QEWI) every five years to inspect exterior walls, submit a technical safety report to the Department of Buildings, and complete necessary structural repairs promptly.
Adil Shamis
Verified AuthorLead Project Estimator & NYC Construction Specialist • NYC DOB GC #NYC-2005-8942

Suspended scaffold rigging for local law 11 nyc facade inspection on multi-story building
Verified NYC Field ProjectExecutive Briefing for NYC Property Owners & Boards
Key Highlights- Height Threshold: Applies to all residential, commercial, and mixed-use buildings over six stories in New York City.
- Five-Year Staggered Cycles: Filings are divided into Sub-Cycles A, B, and C based on the last digit of the property's tax block number.
- Three Technical Ratings: Facades are certified as Safe, Safe With a Repair and Maintenance Program (SWARMP), or Unsafe.
- Mandatory Sidewalk Sheds: Any Unsafe condition mandates immediate pedestrian shed installation along all building perimeters within 24–48 hours.
- Licensed Repair Execution: Structural repairs must be executed by a DOB-registered general contractor under active alteration permits.
What Local Law 11 Is and Who It Applies To
Under local law 11 nyc, officially administered by the NYC Department of Buildings as the Facade Inspection & Safety Program (FISP), building owners with structures taller than six stories are legally required to inspect and maintain their exterior building envelopes every five years.
The mandate originated to protect the public from falling masonry and structural envelope degradation. In the Bronx, property owners managing pre-war apartment complexes along the Grand Concourse and Pelham Parkway frequently manage multi-family buildings that trigger this height threshold due to downward street slopes and exposed basement grade elevations. Similarly, across Brooklyn brownstone districts and Manhattan high-rise corridors, exterior brick, terra cotta, and limestone elements face constant thermal cycling and freeze-thaw expansion that erode structural integrity.
The law applies to all residential co-ops, condominiums, multi-family rental buildings, and commercial towers. If any portion of your building exceeds six stories above grade level, compliance with local law 11 nyc is mandatory.
Building height calculations under FISP count above-ground basements if the ceiling height rises more than several feet above adjoining grade levels. Always review your official Certificate of Occupancy.
FISP Cycles and Filing Deadlines
The Department of Buildings enforces FISP inspections on rolling five-year cycles. Compliance windows are divided into three distinct sub-cycles governed by the final digit of the property's NYC tax block number.
During the active cycle 10 facade inspection window, owners must ensure field evaluations and technical reports are uploaded to the DOB NOW: Safety portal before their sub-cycle deadline expires:
Sub-Cycle A covers blocks ending in 4, 5, 6, and 9. Sub-Cycle B covers blocks ending in 0, 7, and 8. Sub-Cycle C covers blocks ending in 1, 2, and 3. Failure to file within your designated window triggers automatic municipal late penalties and exposes ownership to DOB summonses.
What a Qualified Exterior Wall Inspector (QEWI) Checks
Only a New York State licensed Professional Engineer (PE) or Registered Architect (RA) certified by the DOB as a qualified exterior wall inspector can direct an official facade inspection. A QEWI cannot certify a building from the sidewalk with binoculars; physical hands-on evaluations are legally mandated.
The QEWI executes close-up examinations using motorized suspended scaffolds, industrial rope drops, or pipe scaffolding. The inspection encompasses comprehensive hammer sounding of masonry units, measuring parapet plumbness, inspecting mortar joints for required brick pointing in the Bronx, evaluating structural steel lintels for rust jacking, and opening physical cavity wall probes to inspect masonry tie spacing.
All building appurtenances—including fire escapes, balcony railings, air conditioner brackets, roof cornices, and coping stones requiring parapet wall repair in the Bronx—must be individually documented and rated.

Safe, SWARMP and Unsafe Ratings Explained
Following the engineering field evaluation, the inspector classifies the property into one of three official legal categories:
1. Safe: The exterior walls and appurtenances exhibit no structural distress and do not present a safety hazard during the upcoming five-year cycle.
2. SWARMP (Safe With a Repair and Maintenance Program): The facade displays early signs of wear—such as cracked mortar joints or minor spalling—that are not immediately dangerous but will degrade into hazards if unaddressed. Conditions classified as SWARMP must be repaired prior to the subsequent filing cycle; they cannot be repeatedly carried over.
3. Unsafe: The inspector discovers an active hazard, such as fractured brick, detached decorative cornices, or loose coping stones. An Unsafe rating requires the QEWI to file a FISP22 notification with the DOB within 24 hours.
Repairs After an Unsafe or Failed Inspection
When an exterior envelope fails an inspection or receives an Unsafe rating under local law 11 nyc, ownership must mobilize immediately. The DOB enforces strict containment and repair protocols to prevent pedestrian injuries on NYC sidewalks.
To clear hazardous conditions and return your property to compliance, work through the established DOB remediation sequence:
- 1Immediately install a pedestrian sidewalk shed along all perimeter frontages within 24 to 48 hours to protect street-level foot traffic.
- 2Obtain comprehensive architectural and structural repair specifications from your engineering team detailing required masonry repointing, tie replacement, and lintel repairs.
- 3Hire an experienced DOB-licensed general contractor to pull Alteration Type 2 permits and rigging approvals.
- 4Execute physical masonry restoration, structural brick reconstruction, and lintel rehabilitation using skilled mechanics.
- 5Have the QEWI conduct a final close-up verification inspection and submit an amended FISP report to the DOB to upgrade the building to Safe.
Costs and Fines for Non-Compliance
Ignoring FISP inspection deadlines or neglecting required facade maintenance creates severe financial penalties and legal liability. Unresolved conditions lead to active local law 11 violations on the building's property profile, hindering sales, lease renewals, and refinancing.
The typical cost of a FISP inspection ranges from $5,000 to $25,000 depending on building perimeter, height, and architectural complexity. Repair costs vary depending on the extent of masonry deterioration, parapet instability, and sidewalk shed rental duration.
| Compliance Category | Description | Required Legal Action | Resolution Timeline | Typical Estimated Cost |
|---|---|---|---|---|
| Initial FISP Inspection | Mandated 5-year QEWI review | Hands-on scaffold drops & report filing | 2–6 weeks | $5,000 – $25,000+ |
| Safe Classification | Envelope in sound structural condition | File report and retain documentation | Every 5 years | $0 repairs (filing fee only) |
| SWARMP Classification | Non-critical exterior wear | Scheduled preventative maintenance | Before next cycle | $10,000 – $60,000+ |
| Unsafe Classification | Active hazard or falling debris risk | Erect sidewalk shed; execute repairs | 90 days | $35,000 – $250,000+ |
| Failure to File Penalty | Missed sub-cycle filing deadline | Submit report and pay accumulated fines | Immediate | $5,000 fine + $1,000/mo |
| Failure to Correct Penalty | Unremediated Unsafe condition past 90 days | Request DOB extension or face summons | Monthly recurring | $1,000 – $2,000/mo |
How to Choose a Contractor for FISP Repairs
Executing exterior facade repairs on an occupied high-rise or mid-rise property requires specialized rigging certifications and comprehensive insurance. Standard residential contractors cannot legally rig suspended scaffolding or pull commercial facade permits in NYC.
When selecting a contractor for your FISP restoration, verify active DOB General Contractor registration, dedicated 'Action Over' scaffolding liability insurance coverage, and demonstrable experience in NYC facade restoration services. Working with an experienced contractor ensures that public sidewalk sheds, street permits, and engineering sign-offs are handled seamlessly.

Frequently Asked Technical Questions
Engineering answers addressing NYC Department of Buildings codes, permits, Local Law 97, and roofing specifications.
Local Law 11 in NYC, officially termed the Facade Inspection & Safety Program (FISP), is a municipal building safety law requiring owners of buildings over six stories to periodically inspect and repair their exterior walls. Enacted by the New York City Council to prevent facade collapses and protect pedestrian safety, the mandate requires comprehensive visual and hands-on examinations of all exterior elevations every five years, with technical reports submitted directly to the NYC Department of Buildings (DOB).
Adil Shamis
Licensed NYC General Contractor (#NYC-2005-8942) providing commercial flat roofing, parapet wall rebuilding, facade restoration, and DOB compliance across Manhattan, Brooklyn, Queens, the Bronx, and Staten Island since 2005.